Durapipe PLX helps maintain power for HSBC data centre

Published:  06 January, 2012

Durapipe, pipework
Supporting the standby-power requirements of a new data centre in Yorkshire is Durapipe PLX pipework to transport fuel oil underground from the holding tank to eight bulk tanks and day tanks.

A key role in the operation of a new £150 million data centre for HSBC in Yorkshire is played by the Durapipe PLX pipe-in-pipe specialist fuel pipework system to deliver fuel oil from storage tanks to standby generators in the case of an emergency. M&E contractor ASEE supplied and installed this pipework system for the centre at Normanton.

The pipework is underground, so a system was needed that would ensure fuel oil will not leak into the ground. Durapipe PLX pipework in sizes 50/63 mm and 90/160 mm was installed to carry fuel oil from the 30 000 l holding tank to eight bulk tanks, which in turn supply the day tanks for the generators. PLX has a design life of 30 years.

Stuart Davies of ASEE explains, ‘The product material characteristics and specifically the pipe-in-pipe aspect as it could be monitored with a leak-detection system above ground, was the deciding factor for us, as we needed to be confident we would not be accountable for fuel leaking out into the ground.’

For more information on this story, click here:  Jan 2012, 131

comments powered by Disqus

Search

Welcome

Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.
October 2018: DIGITAL EDITION

ARCHIVE OF DIGITAL EDITIONS

Modern Building services has a group
on Linkedin - join us!

BESA conference 2018

Show

Jobs

  • Senior Building Services Engineer

      Invitations are invited from experienced Building Services Engineers to assist in the development of a new division within an established professional practice. The projects will be predominantly with Defence-related and Government establishments but w......

  • Building Energy Management Systems (BEMS) Engineer

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

  • Engineering Technical Assistant

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

more jobs »

Poll

"Is the Building Services industry lagging behind in the implementation of BIM?"



Calendar