KNX room thermostat

Published:  06 August, 2012

KNX, controls, BMS, BEMS

IMP, a member of the KNX UK Association, now offers the Vimar KNX room thermostat for heating and air-conditioning applications to the UK market. It can interact with other thermostats and with a supervision centre such as a PC in the reception or plant area of a building.

These thermostats can control two temperature zones independently and control the operation of heating/air-conditioning systems based on the average of the temperatures measured by the thermostat’s temperature sensors.

The thermostat is provided with a programmable relay that can be used for generic applications such as switching on lights, closing a zone solenoid valve or activating an electric towel heating.

A programmable digital input can be used for applications such as detecting an open window.

Using the front buttons on the thermostat, the temperature for the room can be set and also to control the speed of the fan-coil unit.

Operating range is -5 to +45°C indoors, with a reading accuracy within ±0.5 K from 15 to 30°C and ±0.8 K at other temperatures.

For more information on this story, click here: August 2012, 100

comments powered by Disqus

Search

Welcome

Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.
November 2018: DIGITAL EDITION

ARCHIVE OF DIGITAL EDITIONS

Modern Building services has a group
on Linkedin - join us!

Jobs

  • Senior Building Services Engineer

      Invitations are invited from experienced Building Services Engineers to assist in the development of a new division within an established professional practice. The projects will be predominantly with Defence-related and Government establishments but w......

  • Building Energy Management Systems (BEMS) Engineer

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

  • Engineering Technical Assistant

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

more jobs »

Poll

"Is the Building Services industry lagging behind in the implementation of BIM?"



Calendar