Trench system delivers heating, cooling and ventilation

Published:  03 December, 2012

Jage, space heating, trench heating

Heating cooling and ventilation are provided from a single trench system using Jaga’s Quatro Canal system. Designed for a 4-pipe set-up , this contemporary-looking and discreet system is just 270 mm wide to minimise visual impact on a building’s design and layout. It is equally suitable for use with a traditional boiler of low-temperature renewable heating systems.

Each unit includes a dynamic 4-pipe heat exchanger and up to four tangential thermic activators that can be controlled by a BMS or room thermostat to provide a smooth transition between heating and cooling.

There are four sizes from 800 to 1800 mm. The largest unit delivers over 3.5 kW of heat at 75/55°C flow/return to achieve a room temperature of 20°C or 1088 W of cooling at 7/12°C flow/return to achieve a room temperature of 25°C, non-condensing. However, there is an integral condensate tray.

These units are 130 mm deep and have noise levels of 30 dB(A). Telescopic feet enable the height to be adjusted to align with raised floors.

A range of grille finishes is available — wood, natural aluminium and lacquer-coated aluminium.

For more information on this story, click here: Dec 2012, 184

comments powered by Disqus

Search

Welcome

Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.
October 2018: DIGITAL EDITION

ARCHIVE OF DIGITAL EDITIONS

Modern Building services has a group
on Linkedin - join us!

BESA conference 2018

Show

Jobs

  • Senior Building Services Engineer

      Invitations are invited from experienced Building Services Engineers to assist in the development of a new division within an established professional practice. The projects will be predominantly with Defence-related and Government establishments but w......

  • Building Energy Management Systems (BEMS) Engineer

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

  • Engineering Technical Assistant

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

more jobs »

Poll

"Is the Building Services industry lagging behind in the implementation of BIM?"



Calendar