Adiabatic humidifier achieves close control

Published:  06 April, 2017

Condair, adiabatic humidification, humidity, relative humidity

Condairís DL in-duct adiabatic humidifier offers the accuracy of humidity control normally only associated with steam humidifiers, but with the low-energy performance and evaporative-cooling benefit of a cold-water system. It also incorporates many anti-bacterial features that make it one of the most hygienic humidifiers available.

This hybrid humidifier combines spray and evaporative technologies to maximise moisture absorption and achieve humidity control of Ī2% RH. A water-treatment system provides pure water to a grid of nozzles in the duct. The nozzles spray towards a ceramic droplet separator that has the dual action of preventing aerosols travelling down the duct and offering secondary evaporation through its porous surface. This increases the efficiency of the system, with 95% of the spray water evaporating during both processes.

The spray nozzles initially operate in stages to meet a required output and humidity demand, after which fully modulating control is achieved by increasing the water pressure to the nozzle to achieve accurate RH control.

The humidifier incorporates a reverse-osmosis water-treatment system to ensure that only pure water is introduced into the airstream. The pure water is also treated with a silver ionisation process that inhibits microbial growth and has a residual effect throughout the humidifier.

Flush and drain cycles prevent water remaining in the system to stagnate. Optional compressed-air drying guarantees moisture cannot remain in the water line. Optional hydrogen-peroxide disinfection can be incorporated into the system.

Being an adiabatic humidifier, evaporative cooling can be provided during the warmer months, with 1 kW of electrical power delivering over 680 kW of cooling.

For more information on this story, click here: April 2017, 161

comments powered by Disqus

Search

Welcome

Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.
October 2018: DIGITAL EDITION

ARCHIVE OF DIGITAL EDITIONS

Modern Building services has a group
on Linkedin - join us!

BESA conference 2018

Show

Jobs

  • Senior Building Services Engineer

      Invitations are invited from experienced Building Services Engineers to assist in the development of a new division within an established professional practice. The projects will be predominantly with Defence-related and Government establishments but w......

  • Building Energy Management Systems (BEMS) Engineer

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

  • Engineering Technical Assistant

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

more jobs »

Poll

"Is the Building Services industry lagging behind in the implementation of BIM?"



Calendar