Research reveals energy-saving potential of natural ventilation in shopping centres

Natural ventilation Windowmaster
Mathematical modelling of WindowMaster natural ventilation combined with mechanical ventilation has demonstrated the potential for large energy savings in shopping centres.
There is huge potential to save energy in shopping centres using a combination of natural and mechanical ventilation to maintain indoor environmental quality, according to a new study. The beneficial effects of natural ventilation in buildings such as schools have been well documented, but until now there has been little work on how the system can be applied to large areas with a mixture of enclosed areas and common internal open spaces — such as shopping centres. WindowMaster, a major provider of natural-ventilation solutions in Europe, commissioned three case studies based on mathematical modelling to show how natural ventilation combined with mechanical ventilation can reduce energy consumption in shopping centres. The thermal simulations were for a 12-month period. The studies found that reliance on mechanical cooling systems can be reduced by introducing natural ventilation and night cooling into environmental control systems to remove heat gains from lighting, people and electronic equipment. Steen Hagelskjaer, co-author of the report, says, ‘The pilot study analysed the energy consumption and indoor environment quality of four types of ventilation using thermal building simulations in three different models of store found in a typical shopping centre. ‘A hybrid solution consisting of automatically controlled natural ventilation and night cooling with assisting mechanical ventilation, cooling and heating, showed the most promising energy-saving potential. ‘The savings are made by supplementing energy-sapping mechanical heating and cooling systems with natural ventilation. To ensure a comfortable and productive indoor environment, mechanical ventilation with cooling should also be installed.’
For more information on this story, click here: April 08, 64
Related links:



modbs tv logo

First keynote speakers announced by Europump

The first two keynote speakers have been announced for an annual event being hosted by the British Pump Manufacturers Association (BPMA).

‘Landmark’ prosecution of online seller welcomed by REFCOM

The air conditioning and refrigeration industry’s largest safety register REFCOM has welcomed the successful prosecution of online sales company Appliances Direct (AD) for breaching F-Gas Regulations.