Fan-coil units help achieve BREEAM ‘Excellent’ rating

Published:  08 March, 2010

Ability Projects, fan coil unit, FCU, Matrix
The capability of Matrix fan-coil units from Ability Projects to closely control air conditioning in Bristol’s Paragon office building has helped it achieve a BREEAM ‘Excellent’ rating.

Contributing to the achievement of a BREEAM ‘Excellent’ rating for the Paragon office building in Bristol is air conditioning based on Matrix fan-coil units from Ability Projects. These units incorporate energy-efficient EC/DC motors to provide infinitely variable speed control of the entire unit, as well as each fan. Each air duct can thus be balanced for air volume through duct speed alone, eliminating the need for noisy volume-control dampers and their time-consuming installation.

These FCUs can also adjust air volume according to room occupancy or thermal demand — or a combination of the two.

The 6-storey Paragon building offers some 7000 m2 of grade A office accommodation and ancillary retail space. Air conditioning is supplied to the office floors by 94 concealed 4-pipe ceiling cassettes with nominal heating/cooling capacities of 5 kW and operating at NR34 noise rating at 30 Pa resistance.

The Matrix system is fitted with a BACnet open-protocol intelligent controller, factory prewired to the FCU and complete with dedicated software. This specially developed controller operates the modulating valve and senses the temperature onto the coil. It also offers wireless access from a laptop computer without having to access the ceiling void.

For more information on this story, click here: March10, 127

comments powered by Disqus

Search

Welcome

Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.
October 2018: DIGITAL EDITION

ARCHIVE OF DIGITAL EDITIONS

Modern Building services has a group
on Linkedin - join us!

BESA conference 2018

Show

Jobs

  • Senior Building Services Engineer

      Invitations are invited from experienced Building Services Engineers to assist in the development of a new division within an established professional practice. The projects will be predominantly with Defence-related and Government establishments but w......

  • Building Energy Management Systems (BEMS) Engineer

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

  • Engineering Technical Assistant

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

more jobs »

Poll

"Is the Building Services industry lagging behind in the implementation of BIM?"



Calendar