Daikin tailors its Altherma system for apartments and community heating
Published:  07 July, 2010
Daikin, altherma, space heating

A version of Daikin’s Altherma system for apartment buildings and community heating can deliver flow temperatures of 80°C for heating and achieve DHW temperatures of up to 70°C. COPs are up to 3.5. Cooling is also an option, with leaving water temperatures down to 5°C. Outdoor units use R410A and offer heating outputs from 23 to 45 kW; they can be grouped for higher outputs.

Compared with individual gas-fired boilers, a 27% reduction in primary energy use is claimed, along with 59% lower CO2 emissions and 33% lower operating costs.

A small indoor unit in each dwelling receives heat from the central outdoor unit and boosts its temperature further using a cascade heat pump on R134a to serve underfloor heating, radiators or heat-pump convectors as required. The indoor unit can include an optional 200 l DHW cylinder storing water at 70°C and thus able to deliver 400 l at 40°C. There are two sizes of indoor unit — 6 and 9 kW.

Connections between indoor and outdoor units are by small-diameter refrigerant piping. Buildings up to 50 m high can be served, assuming the outdoor units are on the roof.

Each apartment has an intelligent user interface with optional wired or wireless room thermostats. Features include weather-dependent setpoint and room-temperature compensation.




Search

Welcome

Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.
October 2018: DIGITAL EDITION

ARCHIVE OF DIGITAL EDITIONS

Modern Building services has a group
on Linkedin - join us!

BESA conference 2018

Show

Jobs

  • Senior Building Services Engineer

      Invitations are invited from experienced Building Services Engineers to assist in the development of a new division within an established professional practice. The projects will be predominantly with Defence-related and Government establishments but w......

  • Building Energy Management Systems (BEMS) Engineer

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

  • Engineering Technical Assistant

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

more jobs »

Poll

"Is the Building Services industry lagging behind in the implementation of BIM?"



Calendar