Myson adds intelligence to fan convectors

Published:  01 September, 2011

Myson, fan convector, space heating

Myson’s iVector range of fan convectors can provide high heat outputs from low water temperatures. and respond rapidly to a room’s heating requirements. There are five models, each with three fan speeds and capable of providing heating and cooling. Maximum outputs range from 4.1 to 11.7 kW with flow/return temperatures of 75/65°C and a room temperature of 20°C, falling to about 40% at minimum fan speed. With flow/return of 45/35°C and a room temperature of 20°C maximum outputs range from 1.4 to 4.4 kW, falling to about 40% at minimum speed.

Sensible cooling performance is up to 3.3 kW.

The low water content of these fan convectors gives a rapid response to heating requirements.

Other features include a 24/7 timer, lockable LCD backlit display, flexible connection options, a range of filter choices, automatic fan-speed control and an option to link to building-management systems.

For more information on this story, click here:  Sept 2011, 174

comments powered by Disqus

Search

Welcome

Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.
October 2018: DIGITAL EDITION

ARCHIVE OF DIGITAL EDITIONS

Modern Building services has a group
on Linkedin - join us!

BESA conference 2018

Show

Jobs

  • Senior Building Services Engineer

      Invitations are invited from experienced Building Services Engineers to assist in the development of a new division within an established professional practice. The projects will be predominantly with Defence-related and Government establishments but w......

  • Building Energy Management Systems (BEMS) Engineer

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

  • Engineering Technical Assistant

      Consistently rated amongst the world's best universities, Imperial College London is a science-based institution with a reputation for excellence in teaching and research. Imperial has one of the largest and most diverse university estate portfolios in......

more jobs »

Poll

"Is the Building Services industry lagging behind in the implementation of BIM?"



Calendar