Airedale and Barkell deliver cooling solution for ACC Liverpool

Published:  03 June, 2015

air conditioning, Airedale, Barkell, AHU

Airedale and AHU manufacturer Barkell worked with the M&E contractor to design and engineer an energy-efficient and resilient cooling solution for the latest addition to ACC Liverpool, currently home to BT Convention Centre and Echo Arena.

The solution comprises 17 combined air-handling and refrigeration units installed on the roof. There are also five air-handling units.

The units feature a variation of Airedale’s Enviropack cooling-heat-pump system. Enviropack is an integral packaged unit that removes the need for external chillers, dry cooler or condensers.

The single-circuit or dual-circuit packs can have one or two compressors per circuit to provide up to four stages of cooling control to maximise part-load efficiency.

Thermal wheels achieve at least 65% efficiency in both summer and winter operation.

The units also incorporate electronic expansion valves to improve EER by up to 30% compared with standard thermostatic expansion valves.

All assembly work and testing was carried out before despatch from the plant.

For more information on this story, click here: June 2015, 83

comments powered by Disqus



Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.


Modern Building services has a group
on Linkedin - join us!


  • Intermediate / Senior Mechanical Engineer

    The Mechanical team undertake the design and specification of a range of Mechanical building services in a lead or supporting role, depending on project complexity and scale. You should demonstrate a flexible approach to design and team working and wil......

  • Senior Urban Designer

     Applicants will be Master’s Degree qualified Architects / Urban Designers, with a strong portfolio of work highlighting a variety of projects at a range of scales and types, with strong focus on regeneration, infrastructure-led projects and major develo......

  • Principal Structural Engineer

    We are currently recruiting on behalf of a global client, with a diverse range of award winning projects to their name. Their experience spans a host of market sectors, including transport, infrastructure, defence, scientific, education, high-tech and ......

more jobs »


"Is the Building Services industry lagging behind in the implementation of BIM?"