EnOcean’s Bluetooth LED-lighting solution

Published:  05 July, 2017

EnOcean’s Easyfit range of wireless self-powered switches for Bluetooth lighting systems provide a maintenance-free ready-to-use solution for LED lighting. Combined with self-powered Bluetooth lighting systems from Casambi, Silvair and Xicato, Easyfit wall switches offer lighting installers the benefits of freely positionable switches that provide flexible control and intuitive usage.

Easyfit switches can be commissioned by near-field communication (NFC) to provide simple or complex lighting schemes and effects.

For more information on this story, click here: July 2017, 162

comments powered by Disqus

Search

Welcome

Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.
July 2017: DIGITAL EDITION
ARCHIVE OF DIGITAL EDITIONS

Modern Building services has a group
on Linkedin - join us!

Construction Week

Show

Jobs

  • Property Surveyor

    Property Surveyor/ Building Service Surveyor needed to work within the Technical Services team for the management of water hygiene/ legionella risk within DCC's property portfolio. We are looking for an experienced and dynamic team member to join our T......

more jobs »

Poll

"Is the Building Services industry lagging behind in the implementation of BIM?"



Calendar