Modular boilers deliver 1 MW from 1 m2 of floor

Published:  05 July, 2017

Hamworthy Heating, boiler, space heating

Hamworthy Heating’s Upton range of floor-standing modular boilers comprises 18 models with outputs from 100 to 1050 kW. They are rated at 6 bar and have a modulation ratio of 5:1 per module. An output of 1 MW can be provided from less than 1 m2 of floor space.

The sectional aluminium-alloy heat exchanger has a low water content; it has exceptional heat-transfer properties and even heat distribution. Modules stack vertically

Pre-mix burners have NOx emissions of less than 40 mg/kWh. Noise levels are less than 60 dB(A).

The Siemens LMS controller provides close control of individual modules and con sequence an additions 15 boilers in a cascade or unison formation.

Upton boilers are delivered fully assembled and have an air-inlet filter to maintain particle-free air form clean combustion.

Condensate traps connect from each boiler to simplify pipework and servicing.

The combustion analyser is at the front of the boiler for ease of access during maintenance.

Optional pipework kits are designed with the complete solution in mind. They can be installed before boilers are put into place and come with features such as a connection for pressurisation units and flushing points. All dirt is collected in one spot and can be easily flushed from the pipe kit.

Along with an integrated non-return valve to prevent combustion gases entering non-firing boilers, these kits facilitate cascade arrangements for installations up to 4.2 MW.

There is also a low-loss header with integrated air and dirt separator specifically designed for the Upton boiler.

For more information on this story, click here: July 2017, 166

comments powered by Disqus

Search

Welcome

Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.
September 2017: DIGITAL EDITION
ARCHIVE OF DIGITAL EDITIONS

Modern Building services has a group
on Linkedin - join us!

Construction Week

Show

Jobs

  • Field Sales Executive

    Successful professional technical salesperson required to sell to consultants and contractors. Unique opportunity to sell ultra-low energy, patented technology, ventilation products from a UK manufacturer. ...

  • Property Surveyor

    Property Surveyor/ Building Service Surveyor needed to work within the Technical Services team for the management of water hygiene/ legionella risk within DCC's property portfolio. We are looking for an experienced and dynamic team member to join our T......

more jobs »

Poll

"Is the Building Services industry lagging behind in the implementation of BIM?"



Calendar