Big Foot steps up

Published:  05 June, 2018

Big Foot

Big Foot Systems has supplied a custom plant deck to support a chiller on the asphalt roof of Manchester Royal Infirmary. Big Foot Technical worked with the contractors to design a solution that allowed the chiller to sit above existing pipework whilst allowing the chiller to remain fully accessible for maintenance (pictured)

The result was a customised plant deck which sits approximately 1m above the roof level to allow for pipe runs. It has a platform around the perimeter of the chiller for maintenance access. Big Foot also provided steps either side of the chiller, to enable access from both sides of the pipework, removing the need for step overs in another location. Big Foot Technical used foot pressure calculations, UDL (roof load) figures and a wind summary to ensure that the design was fit for purpose.

“It was important to supply a support solution that was not only fit for the roof and weather conditions but that also provided suitable access to the plant” explained Peter Mellor, sales manager at Big Foot Systems. “The design that our technical team produced spreads the load of the chiller safely and evenly, and provides safe access too.”

Big Foot Plant Deck Frames facilitate multiple VRF/VRV installations with access requirements or restrictions. The frames offer fast install and benefit from a wide base making them very stable.

For more information on this story, click here: June 2018, 121

comments powered by Disqus

Search

Welcome

Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.
June 2018: DIGITAL EDITION

ARCHIVE OF DIGITAL EDITIONS

Modern Building services has a group
on Linkedin - join us!

Jobs

  • Energy and sustainability: Performance and analysis manager

     An exciting opportunity will arise shortly for an exceptional person with extensive experience of managing sustainability within large complex organisations. Can you demonstrate extensive experience of energy management, proven ability to drive program......

more jobs »

Poll

"Is the Building Services industry lagging behind in the implementation of BIM?"



Calendar