Dimplex ground-source heat pumps provide heating and passive cooling

Dimplex, ground-source heat pump, GSHP, renewable energy
Groundwater and Dimplex heat pumps provide space heating for Vanguard House at Sci-Tech Daresbury, as well as passive cooling in the summer.

A Dimplex ground-source heat-pump system is providing low-carbon heating and passive cooling for a new building at SciTech Daresbury in Cheshire. Vanguard House, a 3600 m2 three-storey office and laboratory facility, was designed to achieve a BREEAM ‘Excellent’ rating and does not use any fossil fuels.

Designed and installed by Dimplex expert partner Ecovision Systems, the systems uses two heat pumps to provide 260 kW of heating capacity at a maximum temperature of 60°C. These heat pumps are reversible to provide passive cooling during the summer. In cooling mode, a flow temperature of 18°C is sufficient to cool the building, so no active chilling is necessary.

In addition, a 40 kW high-temperature heat pump provides all the domestic hot water, achieving a flow temperature of 70°C.

Vanguard House is above one of the largest natural aquifers in the UK, the Permo-Triassic sandstone. Groundwater is plentiful, so Ecovision developed an open-loop system drawing water from a depth of 65 m and passing it through a heat exchanger before re-injecting it into the ground at depths of up to 150 m — removing any risk of groundwater flooding into service channels and basements.

Because the system provides heating and cooling, the net change in groundwater temperature is limited.

The average temperature of water from the aquifer is 10 to 12°C, and the heat pumps can achieve a COP of 4.2. Heating and cooling is delivered to offices and laboratories by a concrete core activation system consisting of pipes embedded into the pre-cast concrete planks that form the floors.

Other design features of Vanguard House include part brise soleil, solar glazing and blinds to help manage temperature changes by reducing solar gain.

For more information on this story, click here: April 2014, 107
Related links:
Related articles:



modbs tv logo

‘Red tape scrapping is welcome – but more policy changes are needed’

The CEO of heat pump manufacturer Aira UK has said the government’s new proposals to scrap planning red tape for the installation of heat pumps in the UK will be a big breakthrough for the industry and consumers – but more policy changes are needed.

New procurement rules for NHS suppliers

New procurement rules mean NHS suppliers will need to demonstrate their green credentials so the NHS can achieve its target of becoming net zero for directly-controlled emissions by 2040, with an ambition to reach an 80% reduction in its carbon emissions between 2028 to 2032.