The highly visible air-conditioning and ventilation system in this new central-London meeting and conference venue is part of the transformation of Garfield House on Edgware Road. Operated by Venues, there are 22 meeting spaces of varying sizes across the three floors — plus breakout and coffee areas.

Specialist installer and Mitsubishi Electric business solutions partner Cool Systems was called in to install the systems.

CS Group technical design engineer Martin Lazovy explained, ‘The brief was to ensure all services were exposed in line with the contemporary design the client was going for, which meant using exposed ducted fan-cool units on the ceilings of each floor.’

Each floor has Mitsubishi Electric Lossnay units to provide mechanical ventilation with heat recovery and City Multi R2 heat-recovery air conditioning using R410A.

The building’s server rooms, pantry and kitchen spaces have smaller split-system air-conditioning units.

A total of 21 Lossnay units of varying sizes were installed.

The system at Garfield House all feeds into an AG150 centralised controller, which can also interlock with the Lossnay ventilation system.

The touchscreen control panel can control up to 50 devices. It has the functionality to monitor energy use, set daily timers and instigate night setback. Upper and lower setpoints can be established, and refrigerant volumes checked via the interface.

Remote control is also provided by panels in the various rooms.

The entire installation can be linked to Mitsubishi’s forthcoming remote management interface, which will enable monitoring and control from iPhones and other smart devices.

For more information on this story, click here: April 2015, 126
Related links:
Related articles:



modbs tv logo

Heat network confidence outpaces progress in social housing

Baxi surveyed 100 housing associations and 102 local authorities and councils responsible for managing or operating heat networks this summer, alongside in-depth interviews with five housing associations, a heat network consultant and heat network contractor.

Signify showcases F1 lighting partnership at Brackley campus

MBS Features Editor Russell Drury was among a group of journalists from across Europe invited to visit the Mercedes-AMG PETRONAS Formula One Team’s headquarters in Brackley, where Signify showcased its partnership with the team and the shared focus on innovation and sustainability.