Trend BEMS integrates with PSBP monitoring system in new school

Published:  01 December, 2016

Trend Control Systems, BMS, BEMS, school

The rebuilding of the Cavendish Close Junior School in a Derby suburb under the Priority School Building Programme (PSBP) includes a building management system from Trend Control System to maximise energy efficiency and help create optimum comfort for pupils and staff. According to The Carbon Trust, reducing energy consumption could help the average secondary school save £21 500 a year in energy bills.

Main contractor Bowmer & Kirkland called in Integrated BMS of Newark, and a Trend Technology Centre, to configure a control solution.

The BEMS was configured to manage and control all the plant and building services. Trend’s IQeco controllers were delivered to site, integrated within mechanical heat-recovery units supplied by Nuaire, a Trend OEM. The units are seamless integrated into Trend’s BEMS, with all the advantages this offers for optimised energy use.

IQeco devices communicate with wall-mounted control units in classrooms to provide fan-speed control, setpoint adjustment and CO2 monitoring so that fresh air can be introduced when needed.

Instead of using TRVs on radiators, the IQeco is configured with an output to enable a PICV (pressure-independent control valve) to control the radiators via the BEMS — which has the advantage of being tamperproof.

The system can be designed to sequence heat recovery and ventilation on just one system, rather than having two systems operating in conflict. This also provides night-time cooling and optimum start/stop functionality.

Once the system was operational, B&K needed to ensure it met the criteria specified in the facilities output specification document, which was generated by the Education Funding Agency (EFA).

Integrated BMS had to find a way for the BEMS to deliver information to a pre-defined benchmarking system and generate information about the operation of the building. This would enable the EFA to ascertain how efficient it is in relation to the original design criteria and compare it to other schools.

Jason Harper, managing director of Integrated BMS, explains that the company was asked to integrate the BEMS with iSERV cmb, which has a database and analysis platform operated by the University of Cumbria. Information is collated regularly and e-mailed to iSERV cmb, which analyses it to devise a benchmarking system. The system was successful and is now used by seven other schools.

Richard Daniels, environmental engineer with the EFA, said, ‘This is the first school we know where the contractor has been able to use the energy-monitoring system specified in the PSBP output specification to validate the commissioning of meters and to get a good picture of the energy end uses in the building as part of the post-occupancy evaluation.’

For more information on this story, click here: Dec 2016, 126

comments powered by Disqus

Search

Welcome

Welcome to Modern Building Services Online, the web edition of Modern Building Services (MBS) journal and the UK's most popular Building Services engineering site. Modern Building Services covers the entire Building Services Engineering industry. This site contains archived content from the journal, plus web-specific content.

When you go to our digital edition, you can also access the archive of digital editions.
March 2017: DIGITAL EDITION
ARCHIVE OF DIGITAL EDITIONS

Modern Building services has a group
on Linkedin - join us!

Jobs

  • M & E Engineering Technician

      We are currently seeking a "team player" with excellent interpersonal skills (ideally with a strong electrical bias) to work as a Building Services Technician providing technical assistance to our experienced and established Engineering Design team. .........

  • Mechanical Engineer (Modelling)

    An opportunity has arisen for an experienced Mechanical (Modelling) Building Services Design Engineer to join our established and experienced team. We are looking for a self-motivated and confident individual, who has a proven track record in the desig.........

  • M & E Clerk of Works

      An exciting opportunity has arisen for a self-motivated, confident Mechanical & Electrical Clerk of Works to join our busy team. You will be providing construction inspection services in conjunction with the delivery of major new build, extensions .........

more jobs »

Poll

"Is the Building Services industry lagging behind in the implementation of BIM?"



Calendar