Chalmor’s 5-minute warning avoids wasted light in plant rooms

chalmor
Chalmor’s BlueWave controllers in eight plant rooms on the Alderley Park site of AstraZeneca ensure that lights are not left on unnecessarily for more than an hour.
The problem of lights being left on unnecessarily in plant rooms at the Alderley Park site of AstraZeneca is being addressed by the installation of Chalmor’s 2-channel BlueWave controller. Des Belford of AstraZeneca’s UKFM explains, ‘It is quite common for lighting in plant rooms to be left on when engineers have finished working, and this can be very wasteful of energy. Presence detectors are an option, but there is always the danger of an engineer being hidden from the sensors behind an item of plant and being plunged into darkness. The solution uses one of BlueWave’s two channels to turn lights off 60 minutes after they have been activated by a pushbutton and the other to sound an alarm five minutes earlier so the lighting period can be extended. At the various entry points to each plant room, there are two push-to-make switches to control the lighting. One switches it on and off, and the other extends the lighting period. When the lights are first turned on, the sounder and flashing beacons operate momentarily to remind the user how the system works. For total safety, a few lights are permanently on to illuminate a strategic way out. In the first hundred days of the installation, lights were on for only about 60 h — indicating the energy that could have been saved by the system. BlueWave controllers have been installed in eight plant rooms on the site, and AstraZeneca plans to roll out the strategy to other plant rooms.
Related links:



modbs tv logo

CHAS urges construction industry to embrace Common Assessment Standard following data sharing agreement roll out

CHAS was the first Recognised Assessment Body to offer the Common Assessment Standard which has fast become the industry’s gold standard for pre-qualification. 

R&D spending in construction sector rose 7.9% last year, despite the pandemic

Construction sector R&D spending hit £368m last year, according to latest ONS data

Calendar