Beyond the EV charger

EV Chargers

Daniel Hewson, CEO at Contactum UK, looks at how the growing adoption of EV chargers, solar PV, battery storage and heat pumps is changing the way domestic electrical installations need to be designed, protected and future-proofed.

For many homes, the arrival of an electric vehicle (EV) charger represents a significant change in electrical demand. But perhaps the more important question is not whether an installation can accommodate an EV charger today, but what else it may be expected to accommodate tomorrow.

The domestic electrical landscape is evolving. EV charging is increasingly sitting alongside solar PV, battery energy storage and heat pumps, while developments such as smart tariffs and bi-directional charging are beginning to change when and how electricity is used.

Individually, none of these technologies are new. What is changing is the likelihood of several being present within the same property. This creates a different challenge for those designing, specifying and installing domestic electrical distribution. Rather than treating each new technology as an isolated addition, there is a growing case for looking at the home as a complete energy system.

An EV charger may be the first major low carbon technology a homeowner installs. Solar PV might follow, then battery storage or a heat pump. Alternatively, these technologies may be specified together as part of a new-build or major refurbishment. Either way, the decisions made around the electrical distribution system can influence how straightforward those later additions are.

Flexibility

Consumer unit capacity is an obvious consideration. Additional technologies can require dedicated circuits and protective devices, increasing the demand for board space. Leaving sufficient spare capacity can therefore provide valuable flexibility. But physical space is only one part of the equation. The overall electrical demand of the property, diversity of loads and how those loads are managed also need to be considered.

This becomes particularly relevant with EV charging. A vehicle can represent a substantial electrical load, but does it always need to charge at full power at the same time as other high-demand equipment is operating? Increasingly, the answer may lie in smarter management rather than simply providing ever-greater capacity.

Load management can help balance demand across an installation, potentially adjusting EV charging in response to other loads within the property. When combined with time-of-use tariffs, solar generation or battery storage, the picture becomes more interesting again.

The question is no longer simply: How much electricity does this home need? It is also: When does it need it? Where is that electricity coming from? And where might it go next?

A home with solar PV, for example, could use excess daytime generation to charge an EV or domestic battery rather than exporting it immediately. Stored energy could then be used later when household demand increases, or electricity prices are higher.

As these technologies become more connected, the distribution system effectively sits at the heart of a much more dynamic energy environment, and changing loads also bring different protection requirements.

Domestic electrical distribution is becoming an increasingly important part of teh energy transition.
Domestic electrical distribution is becoming an increasingly important part of teh energy transition.

Appropriate protection

EV chargers, PV inverters, battery storage systems and heat pumps incorporate power electronics and can produce residual currents with characteristics that differ from more conventional domestic loads. Selecting an RCD purely because it has traditionally been used elsewhere in the home is therefore not sufficient. The appropriate protection needs to reflect the equipment being connected, the manufacturer’s instructions and the requirements of the installation.

This is one area where manufacturers are responding to the changing market. Contactum, for example, has expanded its circuit protection range to include Type B RCDs capable of detecting AC, pulsating DC, smooth DC and multi-frequency residual currents, alongside consumer unit configurations suited to installations incorporating newer electrical technologies. However, the wider point is that protection cannot be separated from the technology it is protecting. As the mix of equipment within homes changes, understanding its electrical characteristics becomes increasingly important.

Perhaps one of the most interesting developments is bidirectional EV charging. Traditionally, the relationship between the grid and the home has been relatively straightforward – electricity arrives at the property and is distributed to the loads that require it. Solar PV and battery storage have already begun to challenge that model.

Vehicle-to-home and vehicle-to-grid technologies could take it another step further by allowing energy stored within an EV battery to be used elsewhere. That raises an interesting prospect. The EV parked on the driveway could eventually become more than another load on the installation; it could become part of the property’s energy infrastructure.

If electricity is increasingly able to move in different directions, at different times and in response to changing demand, the way domestic electrical systems are planned will need to reflect that.

Balance

It is impossible to predict exactly which technologies every homeowner will adopt over the next decade. Nor would it make sense to over-specify every installation in anticipation of equipment that may never be fitted. But there is a balance to be struck.

Thinking about board capacity, protection, load management and likely future requirements when work is first undertaken can be considerably easier than repeatedly adapting an installation as new technologies are added. EV charging therefore provides an opportunity to think beyond the charger.

As homes move from simply consuming electricity towards generating, storing and managing it, domestic electrical distribution is becoming an increasingly important part of the low carbon transition. The challenge is not simply making today’s technology fit. It is creating electrical infrastructure with enough flexibility to accommodate what comes next.

Related links:
Related articles:



modbs tv logo

Heat network confidence outpaces progress in social housing

Baxi surveyed 100 housing associations and 102 local authorities and councils responsible for managing or operating heat networks this summer, alongside in-depth interviews with five housing associations, a heat network consultant and heat network contractor.

Signify showcases F1 lighting partnership at Brackley campus

MBS Features Editor Russell Drury was among a group of journalists from across Europe invited to visit the Mercedes-AMG PETRONAS Formula One Team’s headquarters in Brackley, where Signify showcased its partnership with the team and the shared focus on innovation and sustainability.