Sutton Life Centre buries its ventilation ducts in the ground

Rehau
Ventilation for Sutton Life Centre will be tempered throughout the year by two Rehau Awadukt Thermo ground heat-exchanger systems.

An underground heat exchanger using Rehau’s Awadukt Thermo ground system will reduce the energy requirements of Sutton Life Centre throughout the year. Designed by Curl La Tourelle, this £8 million innovative learning facility will house a citizenship centre, community library and an interactive, virtual-reality space to teach young people a range of life skills. The 2-storey building is being built to meet best-practice sustainability standards.

The temperature of ventilation air drawn through the pipework grids will be reduced by up to 14 K in the Summer and raised by up to 9 K in the Winter, reducing demand on the biomass boiler that is being installed for space heating.

Two grids of Awadukt Thermo pipework are being installed by GSE Civil Engineering following its specification by Halcrow Yolles. The pipework has an anti-microbial silver layer.

The first pipework grid is being installed at a depth of 1.5 m. 11 runs of DN200 runs, each 18 m long, will deliver 2880 m3/h.

A second grid under the multi-use games area delivers 7200 m3/h using 35 runs of DN200 pipework, each 30 m long.

For more information on this story, click here: Sep 09, 129
Related links:
Related articles:



modbs tv logo

Heat network confidence outpaces progress in social housing

Baxi surveyed 100 housing associations and 102 local authorities and councils responsible for managing or operating heat networks this summer, alongside in-depth interviews with five housing associations, a heat network consultant and heat network contractor.

Signify showcases F1 lighting partnership at Brackley campus

MBS Features Editor Russell Drury was among a group of journalists from across Europe invited to visit the Mercedes-AMG PETRONAS Formula One Team’s headquarters in Brackley, where Signify showcased its partnership with the team and the shared focus on innovation and sustainability.