London medical centre prescribes MHI heat-recovery treatment

MHI, air conditioning, VRF
Heating and cooling for this medical centre in Thornton Heath is provided by an MHI VRF air-conditioning system.

Energy-efficient heating and cooling for the new wing of a south-London medical centre is provided by a VRF system from Mitsubishi Heavy Industries. The KXR system at Parchmore Medical Centre in Thornton Heath uses inverter technology and recovery of surplus heat to achieve a CoP of up to 3.4 for a system which qualifies for Enhanced Capital Allowances.

The new Beulah Wing provides six consulting rooms, a minor-operations suite and a staff conference facility.

Supplied by AMP Air, the system was installed by Lee Air Conditioning Services.

The 3-pipe system can provide heating and cooling, using heat extracted from areas requiring cooling to heat other areas.

There are two 8 hp outdoor units with cooling capacities of 22.4 kW and heating of 25 kW. Refrigeration pipework is routed through a duct into the building and into service risers on each floor for distribution to 17 indoor units.

4-way cassettes are installed in most areas with three slimline wall-mounted units serving the lobby, waiting room, and stairway/lift area.

Each indoor unit has its own controls, with a centralised controller in reception. The central unit displays temperature mode and fan-speed settings of each unit and can be used to over-ride localised settings if required.

For more information on this story, click here: Nov 2011, 125
Related links:
Related articles:



modbs tv logo

BSRIA reports sustained global cooling demand as market diverges

BSRIA has released its latest analysis of the global cooling sector. The BSRIA Worldwide Air Conditioning and Heat Pump reports reveal a complex and diverging global cooling market.

CABE awards two new accolades alongside 2026 Honorary Fellowship

At the CABE presidential inauguration on 8th May, the Association was delighted to present two new awards for 2026 alongside its Honorary Fellowship for this year.