A Star solution for a data centre’s cooling needs

Star Refrigeration, Turbocor. data centre
R134a chillers with Turbocor compressors were a key part of Star Refrigeration’s replacement solution for R22 chillers in a data centre.

Existing R22 refrigeration plant in a UK data centre has been replaced with a bespoke cooling system installed by Star Refrigeration using chillers with Turbocor compressors and R134a refrigerant. There are four new chillers, each with a cooling capacity of 1100 kW with variable-speed drives and an air-cooled refrigerant circuit configured for thermosyphon operation to provide free cooling when possible. The previous plant had a cooling capacity of 2700 kW.

Operating as a data centre since 1990, the building has two main data halls with independent power and cooling infrastructure. During 2011, IT and computer server systems in one of the halls were replaced as part of a major refurbishment. Higher air temperatures necessitated a new cooling system with higher capacity.

Alan Walkinshaw of Star Refrigeration explains, ‘Our banking client wanted a cooling solution with up-to-date technology, high efficiency and minimal environmental impact. The solution we adopted was an innovative design using Turbocor R134a compressors and an air-cooled refrigeration circuit. The system is configured to provide free cooling by automatically switching to thermosyphon operation for much longer periods than the previous system.’

Additional AHUs to deal with the increased heat load were mounted on the perimeter of the hall to maintain room air at a supply temperature of 22°C. A new exterior deck was built alongside the existing plant room to accommodate flat-bed air-cooled condensers with variable-speed C fans for low-noise operation and maximum efficiency.

For more information on this story, click here: Jan 2012, 129
Related links:
Related articles:



modbs tv logo

Heat network confidence outpaces progress in social housing

Baxi surveyed 100 housing associations and 102 local authorities and councils responsible for managing or operating heat networks this summer, alongside in-depth interviews with five housing associations, a heat network consultant and heat network contractor.

Signify showcases F1 lighting partnership at Brackley campus

MBS Features Editor Russell Drury was among a group of journalists from across Europe invited to visit the Mercedes-AMG PETRONAS Formula One Team’s headquarters in Brackley, where Signify showcased its partnership with the team and the shared focus on innovation and sustainability.