Top Tips to Cable Management Specification

Legrand, cable management

Cable management is an integral part of the specification process. When it comes to specifying cable management systems, there are a number of key areas to consider in addition to cost per unit and installation time.

Mark Williams, lead marketing manager for cable management at Legrand, talks through some simple top tips during specification.

1. Location

Consider what elements the cable management system will be exposed to. If the system is to be located in a corrosive environment or a marine location for example, the requirements will be very different to that of an internal commercial building installation. Legrand’s industry experts and cable management technical product guides can offer in-depth advice on what to consider when selecting your material.

2. Consider the cable used

It’s important to consider what type of cable will be used throughout the installation and if support or protection is needed.

• Single insulated (non-sheathed) cables require additional mechanical protection (as per BS 7671), as well as support, and therefore an IP4X or IPXXD distribution trunking system is generally the solution of choice as it fully encases the cables.

• If using armoured cables, an open cable management system, such as steel wire cable tray, perforated tray or cable ladder, is considered more suitable.

3. Weight

Calculate the total weight to be supported by the cable management system, taking into consideration current requirements and potential needs in the future.

Remember that the total loading should be calculated based on not only the weight of the cables, but also any ancillary items that are subsequently fitted to the cable management system, such as light fittings, as well as external forces such as weather and the surrounding environment.

4. Regulations and Standards

Wiring regulations can differ depending on the installation or location of the project you’re working on, so it’s imperative to monitor and review the guidelines, prior to an installation.

Amendments to the wiring regulations BS 7671, for example, have to be monitored and respected. This can influence the selection of cable management systems as you may need to opt for a solution that ensures avoidance of premature collapse of the cabling system. In this instance, metallic solutions may be the preferred option.

5. Scalability

It can be tempting to build in redundant capacity during the design and specification stages of a project rather than designing a system that can be easily adapted in the future. Planning ahead has the potential to save businesses time and money in the longer term, so it’s worth considering in the design stages.

Remember, when considering scalability, retrofitting can be expensive and not all systems can be easily integrated with one another. Consider this at the design stage by specifying a system that can easily interface with others.

6. Full range of accessories

Take the time to specify a system that offers a full range of accessories including brackets, fixings and couplers, from one source. Work with your supplier to ensure you specify the correct amount of fittings, brackets and fixings in order to prevent delays on site.

Effective cable management can help to enhance cable performance, longevity and future flexibility in terms of business growth if implemented effectively. There isn’t a “one solution fits all”, so it is vitally important that the correct system is chosen from the outset. By selecting a cable management system that excels in each of these areas, you will not only have a system that reduces installation time, and therefore total installed cost, but you will also have a system that can meet your needs today and tomorrow.

For more information on Legrand’s range of cable management solutions please visit the link below or call 0345 605 4333.

For more information on this story, click here: November 2019, 09
Related links:
Related articles:



modbs tv logo

Heat network confidence outpaces progress in social housing

Baxi surveyed 100 housing associations and 102 local authorities and councils responsible for managing or operating heat networks this summer, alongside in-depth interviews with five housing associations, a heat network consultant and heat network contractor.

Signify showcases F1 lighting partnership at Brackley campus

MBS Features Editor Russell Drury was among a group of journalists from across Europe invited to visit the Mercedes-AMG PETRONAS Formula One Team’s headquarters in Brackley, where Signify showcased its partnership with the team and the shared focus on innovation and sustainability.