Ideal Commercial’s heat-interface units

Ideal Commercial, heat interface unit, HIU, space heating, DHEW

Ideal Commercial Boilers’ range of Logic heat interface units comprises four models. They are designed for multi-residential buildings served by central boiler plant. There are two indirect units (50 and 75) and two direct units (high temperature and medium temperature). All units can be fitted with a heat meter, including one that can be monitored remotely.

The indirect units supply heating and hot water via independent plate heat exchangers. Both models can supply 15 kW of heat. DHW is rated at 50 or 75 kW, depending on the model. They can be adapted to serve underfloor heating. Indirect units do not need a pressure-independent control valve, simplifying and speeding up installation.

The direct units supply hot water via a plate heat exchanger at 50 kW, with heat delivered direct from the primary circuit at up to 10 bar. The medium-temperature unit offers modulation of flow temperature.

Al logic HIUs have a fully insulated cover to minimise heat loss. Electronic control valves adjust quickly to change in the primary-system pressure and secondary demands.

In a correctly sized system, Logic HIUs enable the return water from the primary system to reach a temperature of less than 40°C for hot water and below 50°C for radiator systems, enabling the central plant to operate in condensing mode.

For more information on this story, click here: Nov 2014, 163
Related links:
Related articles:



modbs tv logo

Heat network confidence outpaces progress in social housing

Baxi surveyed 100 housing associations and 102 local authorities and councils responsible for managing or operating heat networks this summer, alongside in-depth interviews with five housing associations, a heat network consultant and heat network contractor.

Signify showcases F1 lighting partnership at Brackley campus

MBS Features Editor Russell Drury was among a group of journalists from across Europe invited to visit the Mercedes-AMG PETRONAS Formula One Team’s headquarters in Brackley, where Signify showcased its partnership with the team and the shared focus on innovation and sustainability.