Control system for The Crystal features KNX

KNX, controls, BMS
Adding to the list of iconic projects using KNX intelligent control is The Crystal sustainable-cities initiative by Siemems.

KNX intelligent building controls play an integral role in the efficient operation of The Crystal in London, the sustainable-cities initiative by Siemens. As an open system, KNX sits alongside and operates seamlessly with other protocols in the building-management system, including BACnet and Modbus. KNX can also be linked to any manufacturers’ building control system.

At The Crystal, KNX provides control of HVAC applications throughout the building, including air-handling units, fans, room controls, windows and roof vents. It also provides demand-controlled lighting levels for individual rooms using passive infra-red controllers, as well as controlled blinds through wall-mounted controllers. There is an interface to the audio-visual system.

This £30 million building has an area of over 6300 m2 and is a conference centre, urban dialogue platform, and technology and innovation centre. It uses solar power, ground-source heat pumps and LED lighting. No fossil fuels are used. Passive design elements include a high-performance facade system. Total electrical consumption is 1467 MWh.

Andy Davis of KNX UK says, ‘KNX was the ideal choice for The Crystal as it allowed multiple disciplines to be easily linked, reducing installation costs and ensuring interoperability. KNX also ensured the building was future proofed, as its flexibility ensures changes can easily be applied as the building changes and adopts new technologies.’

Other KNX installations include The British Library, MediaCityUK, Heathrow Terminal 5, ITV Studios and many others.

For more information on this story, click here: June 2013, 124
Related links:
Related articles:



modbs tv logo

Heat network confidence outpaces progress in social housing

Baxi surveyed 100 housing associations and 102 local authorities and councils responsible for managing or operating heat networks this summer, alongside in-depth interviews with five housing associations, a heat network consultant and heat network contractor.

Signify showcases F1 lighting partnership at Brackley campus

MBS Features Editor Russell Drury was among a group of journalists from across Europe invited to visit the Mercedes-AMG PETRONAS Formula One Team’s headquarters in Brackley, where Signify showcased its partnership with the team and the shared focus on innovation and sustainability.