Matt Maleki, Business Development Manager and IAQ Specialist at Carrier, explains how urgent NHS ventilation upgrades also present an opportunity for long-term air quality improvement.
How early technical collaboration with Axair Fans shaped the fume extraction strategy for one of the UK's most significant laboratory redevelopments.
Improving air quality in problem spaces
Ian Thomas, Product Manager at TROX UK, discusses whether decentralised ventilation can deliver without the need for an air handling unit.
Why fire dampers (really) matter
A close examination of the crucial role played by fire and smoke control dampers in protecting people and property captures the much wider shift in culture needed to address the whole issue of building safety failings, according to BESA’s Technical Director, Kevin Morrissey.
Managing fire damper maintenance: a risk based approach
Maintenance of fire dampers in ventilation systems has been in the news following an awareness campaign about the risks of incorrectly installed units. Building owners and managers can be left in no doubt of the need to inspect and test dampers and rectify installation faults – but it may not be straightforward to do so. In this article, Andrew Steel, Managing Director at Airmec, describes a risk based, pragmatic approach.
Ian Ellis, Marketing Manager at Siemens Buildings, discusses the issue of indoor air quality in education.
Andrew Jones, Technical Director at Axair Fans, explains how strong supplier relationships aren’t defined by the absence of failure. They’re defined by what happens when things get messy.
Diagnosis before prescription: why technical fan support must start with understanding.
Prescribing a solution before diagnosing the problem is a common mistake when managing air movement systems. Correct diagnosis before action can avoid new problems, and save money and trust, sayd Andrew Jones of Axair.
Alun Thomas, Nuaire Engineering Director, discusses how reducing embodied carbon in ventilation systems can provide a critical step toward Net Zero.
Paul Williams, Product Manager at Domus Ventilation, highlights six benefits of residential MVHR systems.
Turning IAQ advocacy into action
As part of Carrier’s Commercial HVAC team, Matt Maleki, Business Development Manager and Indoor Air Quality Specialist, champions Carrier’s ongoing commitment to healthier indoor environments. Here, he discusses why the BESA global IAQ pledge marks a pivotal moment for the industry and how defining a practical ‘Step One’ could turn awareness and intent into meaningful action.
Stuart Smith, Commercial Director at Zehnder Group UK, explains how you can create the perfect indoor conditions with heat and moisture recovery.
Meeting ventilation requirements – now and in the future
Ruth MacEachern, Product Manager at EnviroVent, looks at how the updated Building Regulations are driving the adoption of a system based approach to ventilation.
With the Net Zero 2050 target edging closer and driving energy efficient solutions, as well as an increased focus on health and legislation, building services consultants have a raft of boxes to tick. Matt Cooper, Business Development Director at Breathing Buildings, discusses the latest trends and how hybrid ventilation technology alongside expert technical support offers an ideal low carbon solution.
Achieving compliance with ventilation requirements
Ruth MacEachern, Product Manager at EnviroVent, looks at how to meet the latest ventilation requirements in dwellings as part of improving indoor air quality in buildings.
Extract fans: the unsung heroes
Paul Williams, Domus Ventilation Product Manager, looks at how to select and install a domestic extract fan to ensure high performance and longevity.
Alan Siggins, Managing Director of Airflow, explains the current legislation surrounding the UK’s indoor air quality standards.
Nicola Rivers, Indoor Climate Specialist at Zehnder Group UK, discusses the importance of understanding the impact of condensation in commercial buildings.
Paul Downing, Principal Consultant at Compliance (Air and Water) and member of the of the inaugural 1998 HVCA (Now BESA) Ventilation Hygiene Branch, outlines the amendments to section 11 in the April 2024 first edition of TR19 AIR, rebranded and titled ‘Specification for Internal Cleanliness and Hygiene Management of Ventilation Systems’.
Alex McDonald, Indoor Climate Specialist at Zehnder Group UK, looks at some effective ventilation and indoor climate solutions for optimal learning environments and student success.
David Millward, Group Product Manager at Elta Group, explains why good indoor air quality is now a must, and not just a ‘nice-to-have’.
Gaining a ventilation advantage
The Covid pandemic highlighted the importance of good indoor air quality (IAQ) and ventilation and has given rise to CO2 monitors being used to assess the air within schools. However, guidance already exists for ventilation in schools with BB101. Louise McHugh, Product Manager at Breathing Buildings, explains how the document sets out requirements for educational premises and how by employing the latest hybrid ventilation, consultants can help schools maximise health, comfort and sustainability without significant building works.
Passivent has supplied eleven Airscoop roof mounted terminals for use on a new £3.6 million performance archery facility at Lilleshall National Sports Centre in Shropshire.
Matthew Maleki, CIAT’s indoor air quality champion, explores the significance of the new IEQ standard and what it means for business owners and managers.
Clearing the air on ventilation hygiene
Gary Nicholls, Managing Director of duct cleaning expert Swiftclean, and co-author of TR19®, looks at the long-anticipated TR19® Air specification and what this may mean for ventilation hygiene standards.
Achieving best standards for healthcare
Andrew Robinson, Managing Director of HVAC supplier Exi-tite, explains the role of technical memorandum HTM-03-01 for ventilation in healthcare.
The challenge of over-exposure
Tim Tanner, Product Technical Manager – Ventilation Technology at TROX UK, discusses how air management challenges with exposed ceilings can be overcome.
David Millward, Group Product Manager at Elta Group, discusses how schools must re-assess energy saving priorities and introduce quality-designed mechanical ventilation systems into these crucial buildings.
Building operators need to balance the need for good ventilation and comfort for users, whilst minimising carbon output and energy costs, and measurement is the key to that balance. Andrew Hamshere of Sensing Precision explains how and why.
Delivering good Indoor Air Quality doesn’t have to cost the Earth
The Covid-19 pandemic drew everyone’s attention to the importance of good indoor air quality (IAQ), but there is a danger that these advances in knowledge and action will be lost in the face of the energy and climate crisis. Adam Taylor of ARM Environments says we can have both.
BESA welcomes first British Standard for indoor air quality
The Building Engineering Services Association (BESA) has praised the creation of the first British Standard for health and well-being in buildings.
The invisible threat of indoor air pollution
According to the World Health Organisation Air Pollution - both indoor and out - is responsible for about one in every nine deaths annually and this will only get worse unless we take action to mitigate the risks. What is to be done? Sutart Smith of Zehnder has suggestions.
Heating, ventilation, and air conditioning (HVAC) systems are crucial in maintaining indoor air quality in commercial buildings. Until recently, however, little thought has been given to monitoring the presence of airborne microbes that can profoundly impact our wellbeing.
Dust: Why it’s an issue and what can be done about it
Keeping commercial and industrial environments running safely and efficiently means navigating a range of issues and dealing with threats on all scales to ‘business as usual’. Even those threats that are smaller in stature can have just as great an impact on productivity and staff wellbeing – and it doesn’t get much smaller than dust.
Part L vs Part F - Battle of the regulations
Complying with both Part L and Part F is going to give designers some real headaches. James Price of Spire Building Services Ltd tries to apply some painkillers.
Social housing crisis keeps ventilation in the spotlight
An unprecedented combination of public outrage and government intervention is ramping up the pressure on landlords to tackle the health problems caused by poor ventilation in their buildings, according to Graeme Fox, Technical Director at the Building Engineering Services Association (BESA).
Despite clean air being critical to health, wellbeing and productivity, and having come out the other side of a pandemic, indoor air quality (IAQ) often remains an overlooked matter. We have food hygiene ratings - why not air? David Millward of Elta Fans has a suggestion to make.
Bosch Commercial & Industrial have announced that anyone installing their boiler systems using cascade flues, where there is more than one appliance, will be required to include a carbon monoxide (CO) detector.
Communicating IAQ science to the layperson
Adam Taylor, CEO of ARM Environments, explains it is important that the industry works hard to keep indoor air quality front of mind. Good communication and providing valuable insights will be key to keeping end users engaged in this important issue.
Tim Tanner, Product Technical Manager – Air Diffusers & Attenuators, at TROX UK, reviews the air quality advantages of underfloor ventilation employing floor grilles/diffusers and provides tips on system design.
The pandemic has set new requirements on building services to ensure the safety of building users not only from the current pandemic but future COVID variants and new viruses, says Andrew Hamshere of Sensing Precision. These new requirements not only include higher levels of airflow and ventilation to reduce infection rates, but also the ability to demonstrate these so staff and visitors can feel secure that they are protected as best they can be.
Are your meeting rooms stifling decision-making? Why and how we need to improve indoor air quality
Upgrading buildings’ ventilation, filtration, and other factors would not only decrease COVID transmission but also improve health and cognitive performance in general says Simon Jones of Ambisense.
Stop talking about indoor air quality
It is more than five years since the Grenfell Tower disaster; we have had a pandemic driven by an airborne virus and we are now facing a cost-of-living crisis. Nathan Wood asks: what more needs to happen to get people to stop talking about making buildings healthier, safer, and more efficient and take practical action?
Science & Technology essential for better Indoor Air Quality
Richard Bishop, UK and Ireland Head of Marketing at Panasonic, explains the need for raising awareness around Indoor Air Quality (IAQ) and Air Conditioning Solutions and why science and technology must collaborate to deliver healthier air.
Titon’s powerful but compact HRV1.6 Q Plus MVHR unit has recently been installed in Moda Living’s Lexington Tower.
Improving air quality in our indoor spaces has never been more important. Andrew Robinson of Exi-tite explains why.
It is well established that efficient and effective filtration is one of the foundational pillars of any well-designed building heating, ventilating, and air conditioning (HVAC) system. David Schurk of Global Plasma Solutions and ASHRAE looks at maintaining both efficiency and effectiveness.
Outdoor air pollution in both cities and rural areas was estimated to have caused 4.2 million premature deaths worldwide per year based on 2016 data; with this mortality rate being attributed to exposure to fine particulate matter of 2.5 microns or less in diameter (PM2.5), which causes cardiovascular and respiratory disease and cancers. As designers and operators of building HVAC systems, we have a duty of care to make sure indoor spaces are safeguarded against the dangers posed by what is often referred to as “fresh air”, says Adam Taylor of ARM Environments.
Ensuring the highest quality indoor air means designing and specifying the right ventilation system. In order to do this, however, it is important to acknowledge that each element in a HVAC system has a significant impact on its operational efficiency and quality, says James Gafford of ECEX.
To date, less attention has been given to the quality of indoor air in comparison to outdoor air and pollution. According to SAGE member Professor Cath Noakes, an estimated 15% of all Covid-19 deaths can be attributed to poor air quality, meaning attention is rightly turning to indoor air as well – and ventilation is now one of the biggest challenges facing building and facilities managers today. Hern Yau of Mitsubishi Electric discusses why attention is rightly turning to indoor air quality.
Heat network confidence outpaces progress in social housing
Baxi surveyed 100 housing associations and 102 local authorities and councils responsible for managing or operating heat networks this summer, alongside in-depth interviews with five housing associations, a heat network consultant and heat network contractor.
Signify showcases F1 lighting partnership at Brackley campus
MBS Features Editor Russell Drury was among a group of journalists from across Europe invited to visit the Mercedes-AMG PETRONAS Formula One Team’s headquarters in Brackley, where Signify showcased its partnership with the team and the shared focus on innovation and sustainability.