Leading holiday park enhances hot water system with Rinnai N series for peak season demand

Rinnai Schematic

Rinnai has installed 5 x N Series 1600i units and a 1000L storage cylinder at a leading southwest holiday resort, Northam Farm Caravan & Holiday Park in Somerset, to ensure increased demand is met with a practical, economic, and technically viable new hot water delivery system.

The holiday park, in Brean, Somerset, offers a top-class range of facilities with a selection of bars, restaurants, fishing lakes and access to a beach.

The new hot water delivery system replaced a stored system which instantly lowered carbon and costs as there was no need to constantly re-heat potable hot water. Rinnai units were first installed two years ago – at that time, the install covered twenty-six showers, forty basins, and eight wash-up areas. The installation included 6 x N1600i + 1000L storage.

The installation site was spacious which allowed for Rinnai UK’s design team to suggest a flexible system internally mounted design that met customer requirements. Rinnai can offer a multitude of systems using all fuels and energy saving technologies as solutions for heating and hot water supply to sites of any size.

Rinnai N series continuous flow water heaters arrive with a 12-year extended warranty that safeguards a customer against additional product payments. All appliances are manufactured under strict guidelines of ISO 9001 quality management and ISO 14001 environmental management and come with full manufacturers’ warranty.

Rinnai N Sensei Series continuous flow water heaters are designed to provide domestic and commercial access to vast volumes of cost-effective, clean and temperature controlled hot water. Rinnai aim to supply UK customers with practical, economic, and technical solutions for water heating.

Each Rinnai Sensei N Series water heater unit offers a more compact and enhanced combustion design that allows for convenient installation, superior operational performance, and easy accessibility when servicing is required. All additional components are designed and manufactured by Rinnai ensuring proven quality and reliability.

There are four models in the range.

  • ·       N1600i giving 954 litres per hour.
  • ·       N1600e (external) also giving 954 litres per hour (at 50 degrees).
  • ·       N1300i giving 775 litres per hour.
  • ·       N1300e also giving 775 litres per hours of temperature controlled at 50 degrees.

The two 1600s have load profiles of XXL and are water efficiency class A rated, while the 1300s are load profile XL and are also water efficiency class A rated.

Other features include:

  • Flue up to 30+ metres for concentric
  • Turbo Fan
  • Built-in controller as standard on both internal and external models
  • Cascade Cable assembly allows up to twenty-four water heaters to be connected and function as one total and complete system. Any number of N-series Rinnai water heaters can be manifolded together enabling the largest capacities on the market.
  • Built in flue damper.
  • Air inlet filter
  • Frost Protection – minus 15°C on the internal versions and minus 20 °C on the external versions.
  • New PCB Design
  • Controller as standard – Lockable, set up of appliance, temperature set up to seventy-five.
  • Maintenance Monitor for engineers

The Sensei N Series uses Rinnai’s patented advanced burner technology with a 13-1 turn down ratio – the largest on the market – including extremely quiet operation. Integral controls on the units enable the water heater to achieve high efficiencies due to advanced burner control and high modulation ranges. All designs in this range are low-NOx.

Advanced burner controls with the Sensei N Series models ensure all appliances are well ahead of the NOx requirements set within ERP. The current level of permissible NOx set by ERP is 56 mg/Kwh. The Sensei N Series is third-party tested at 28 mg/Kwh making each unit one of the most ecological water heating appliances available on the market.

As the units do not incorporate storage their ‘green credentials’ are further recognised by BREEAM and score additional credits under the building regulations.

Related links:
Related articles:



modbs tv logo

EBSSA publishes Strategic Skills Plan

The Engineering and Building Services Skills Alliance (EBSSA) has published its strategic Sector Skills Plan, as part of the work undertaken by the Construction Mission Skills Board.

AI automation boosts efficiency at Polypipe Building Services’ manufacturing site

Polypipe Building Services has enhanced manufacturing efficiency, productivity and sustainability through a major programme of automation investment at its production facility in Aylesford.